Comparison of the result and agreement of Troponin T-POCT and Troponin T-Hs tests on myocardial infarction diagnosis

Vu Xuan Huynh, Ta Thanh Van, Le Hoang Bich Nga, Nguyen Van Tuyen, Nguyen Duc Tuan, Nguyen Quoc Cuong, Tran Thi Quynh Trang, Nguyen Thi Ngoc Lan

Main Article Content

Abstract

Myocardial infarction (MI) is an emergency condition, patients need to be diagnosed early and intervene promptly. TnT-POCT can shorten the time to return results,  as such, the quality assurance for Troponin T-POCT test is very important. The study was conducted on 02 QC levels and blood samples of patients indicated for Troponin T-Hs test with the aim of confirming the value of use and evaluating the similarity and consensus of TnT-POCT test and high-sensitivity Troponin T test (TnT-Hs) in diagnosing MI. The results showed that the precision and accuracy of TnT-POCT test at QC level 2 were confirmed to be consistent with the manufacturer's published standards. The results of TnT-POCT and TnT-Hs tests were closely correlated with a correlation coefficient r of 0.92, and high agreement in the diagnosis of MI with a Kappa coefficient of 0.861. However, there was a constant error between the two methods, the median value of the difference is -14.5% which is larger than the allowable deviation, indicating that the results between the two methods are not similar.

Article Details

References

1. Collet JP, Thiele H, Barbato E, et al. 2020 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation. Eur Heart J. 2021;42(14):1289-1367. doi:10.1093/eurheartj/ehaa575
2. Pickering JW, Than MP, Cullen L, et al. Rapid Rule-out of Acute Myocardial Infarction With a Single High-Sensitivity Cardiac Troponin T Measurement Below the Limit of Detection: A Collaborative Meta-analysis. Ann Intern Med. 2017;166(10):715-724. doi:10.7326/M16-2562
3. Collinson PO, Saenger AK, Apple FS, et al. High sensitivity, contemporary and point-of-care cardiac troponin assays: educational aids developed by the IFCC Committee on Clinical Application of Cardiac Bio-Markers. Clin Chem Lab Med. 2019;57(5):623-632. doi:10.1515/cclm-2018-1211
4. Lamia Moheb. Validation of Troponin T Testing Using Roche Cobas h232 (Point of Care Testing). ResearchGate. doi:10.13140/RG.2.1.1471.7683
5. Aldous S, Mark Richards A, George PM, et al. Comparison of new point-of-care troponin assay with high sensitivity troponin in diagnosing myocardial infarction. Int J Cardiol. 2014;177(1):182-186. doi:10.1016/j.ijcard.2014.09.026
6. Christenson RH, Jacobs E, Uettwiller-Geiger D, et al. Comparison of 13 Commercially Available Cardiac Troponin Assays in a Multicenter North American Study. J Appl Lab Med. 2017;1(5):544-561. doi:10.1373/jalm.201 6.022640
7. Lê Hoàng Bích Nga, Hồ Thị Phương, Nguyễn Thị Ngọc Lan. So sánh tương đồng kết quả xét nghiệm định lượng troponin T trên máy xét nghiệm nhanh tại chỗ (poct) cobas h232 và máy xét nghiệm tại phòng xét nghiệm trung tâm cobas 8000. Tạp chí Nghiên cứu Y học. 2022;159(11):229-236. doi:10.52852/tcncyh.v1 59i11.1301
8. Lin Y hui, Zhang Y, Liu Y tao, et al. How to choose a point-of-care testing for troponin. Journal of Clinical Laboratory Analysis. 2020;34(7):e23263. doi:10.1002/jcla.23263
9. Cobas® h 232 POC system. Diagnostics. Accessed May 29, 2024.
10. EP15 A3 User Verification of Precision & Bias Estimation. Clinical & Laboratory Standards Institute. Accessed May 29, 2024.